Wastewater Management
“Effluent out of spec, found out when the inspector arrives”
DO sits above 3 mg/L at night when inflow is low — cut blower run time from 23:00 to 05:00
- The process: inlet pit → aeration → clarifier → discharge
- DO in the aeration tank and pH at the discharge
- Whether the blower is running on measurement or by hand
- Level in each pond against the point that needs watching
Figures on this screen are illustrative; a real one shows readings from your own site.
What you see
- pH or DO slips overnight with nobody watching
- Aeration blowers run around the clock, burning power they don't need
- A pump stops and the pond overflows before anyone knows
What we do
pH, DO and level measured continuously, pumps and blowers monitored, blowers run on the DO actually measured, and the history logged.
How it works
pH, DO and level in the inlet pit, the aeration tank and at the discharge
Gathers the sensors and the pump and blower status, and sends them up
Continuous records on servers in Thailand, ready for reporting
Momosight finds the hours DO runs higher than needed and proposes blower run times that match the load
The whole process, inlet to discharge, on one screen
Blowers run on measured DO, with a LINE alert when a reading leaves its range
What it does
pH and DO measured all the time, not sampled now and then.
Aeration to what the process needs, instead of hours that aren't.
A stopped pump or a rising level is known before the pond overflows.
Any period exported to Excel or PDF charts for the authorities' paperwork.
An early threshold, set inside the value you must hold.
Seen together from one place, with access per site.
Devices used in this system
Prices are per set; how many you need depends on the site.
Where it fits
On-site treatment plants
Shared ponds for several plants
Treatment before public discharge
Plants under offices and condominiums
Treatment in tourist areas
Effluent with a heavy organic load
How we work with you
- 01Survey the plant
The ponds, the pumps and blowers, the points worth measuring and the limits you must hold.
- 02Install and calibrate
Sensors fitted and checked against a reference test kit.
- 03Limits and control rules
DO and pH ranges, the blower's rules, and the operators' LINE group.
- 04Support afterwards
Annual MA, including cleaning and recalibration cycles.
Related documents
Questions about this system
How much upkeep do the sensors need?
Water-quality probes need cleaning and recalibration on a cycle that depends on the effluent. We set that cycle in the MA contract and the system reminds you when it is due.
Is automatic blower control safe?
Limits are set around it — minimum and maximum run times — and manual control is always available. If the connection drops, the equipment falls back to the schedule already set on it.
Can it measure COD or BOD?
What we install measures pH, DO, EC and level continuously. COD and BOD still need samples sent for analysis, but the continuous data shows the trend before the lab result arrives.
Can the data be filed with the authorities?
It supports the paperwork — continuous records, exportable for any period. Legally certified results still have to come from an accredited laboratory.