Smart Generator

The power fails, and the generator doesn't start

What the screen looks like
Live · Secured
Generator Fuel Level
82%
ready on standby
UtilityGGEN-1STANDBYATSLoad312 kWFUEL82%BATTERY25.8 VRUN HOURS1,184 h
AI Insight

Battery dipped to 21.4 V on the test start, 9% lower than last month — replace it before the next test

Genset GEN-1 · 500 kVA
Modbus · Controller
STANDBY
ATS-1
Modbus · MDB
UTILITY
Start Battery
Analog · 24 V
25.8 V
  • The supply path: utility and generator through the ATS to the load
  • Fuel level now, with a bar for what is left in the tank
  • Battery voltage and accumulated run hours
  • Whether the set is ready on standby

Figures on this screen are illustrative; a real one shows readings from your own site.

What you see

  • The starter battery wears out and nobody notices
  • Fuel runs low or is siphoned off, found out only when it's needed
  • No one knows the run hours have reached the service interval

What we do

Fuel level, battery voltage, engine and ATS status and run hours all watched, with a LINE alert the moment anything is off.

What you get: Confidence the set is ready on standby, and maintenance planned from real run hours.
Fits: Hospitals · Data centres · High-rises · Telecom sites

How it works

01
Sensors at the set

Battery voltage, engine and ATS status, run hours and fuel level

Modbus · WiFi · 4G
02
Gateway

Reads the controller over Modbus and sends it up over WiFi or a 4G SIM

MQTT / HTTPS
03
Cloud

Test-run history and readings kept on servers in Thailand

History
04
AI analysis

Momosight compares each test start and spots a battery weakening before the day it is needed

AI insight
05
Dashboard

Readiness of every set, at every site, on one screen

LINE · Email
06
Alerts and PM

LINE when a reading is off, and a reminder when run hours reach the service interval

The platform also speaksBACnetOPC UATelegram

What it does

Fuel level, continuously

The level now, and any fall that shouldn't be happening — like one while the set is idle.

Starter battery health

Voltage at rest and during a test start, so the trend shows before a failure to start.

Engine and ATS status

Whether power is coming from the grid or the set, and when the ATS changed over.

Run hours and service

Hours accumulated, with a reminder at the interval you set.

Test-run records

Every run logged with its readings — evidence the set is maintained.

Many sites, one system

Organisations with sets in several places see them all together.

Devices used in this system

Prices are per set; how many you need depends on the site.

Where it fits

Hospitals

Backup that cannot fail

Data centres

Readiness that has to be provable

High-rises

Backup for lifts and fire systems

Telecom and substations

Sites with nobody on hand

Factories

Lines that cannot stop

Public agencies

Where test records are required

How we work with you

  1. 01
    Survey the set

    The engine, its controller and communication ports, and the fuel tank.

  2. 02
    Install and test

    Wire the controller signals, fit what is needed, and prove it with a real start.

  3. 03
    Thresholds and PM

    Fuel and battery limits, hours to service, and the engineering team's LINE group.

  4. 04
    Support afterwards

    Annual MA with remote and on-site support.

Related documents

Questions about this system

Which generators does it work with?

Any whose controller offers Modbus or status contacts. Tell us the engine and controller models and we will check before quoting.

Does measuring fuel mean cutting the tank?

It depends on the tank and the sensor. Many tanks already have a fitting; our engineers assess it and propose an approach that leaves the tank intact.

What if there is no internet there?

There are 4G SIM versions, which suit plant rooms and telecom sites where WiFi does not reach.

Does it help with the monthly test run?

Yes. Every run is logged with the readings from it, which serves as the record that the test happened and the set was fit to use.

Other solutions