Smart Air Compressor

The compressor runs all day, and nobody knows where the air goes

What the screen looks like
Live · Secured
System Air Pressure
7.2bar
LOADED 68%
COMP-175 kW7.2 barRECEIVERAIR LINE12.4 m³/minLOADED68%ENERGY0.10 kWh/m³DEW POINT3.2 °C
AI Insight14% saved

The compressor ran 2 h 40 min on a night with no production — about 14% of the day's air leaking away; check the pipework in the assembly area

Compressor COMP-1 · 75 kW
Modbus · Compressor room
LOADED
System pressure
Sensor · Receiver
7.2 bar
Dew point
Sensor · Dryer outlet
3.2 °C
  • System pressure and current flow
  • Time loaded against time running unloaded
  • Energy per cubic metre of air produced
  • Dew point — the quality of the air reaching the line

Figures on this screen are illustrative; a real one shows readings from your own site.

What you see

  • Its power is high but cannot be separated from the plant's total
  • It keeps running when production has stopped — usually a leak in the pipework
  • Pressure is set high to be safe, without knowing what the work really needs

What we do

Power, pressure, flow and dew point measured continuously, run hours set against real production time, energy worked out per cubic metre of air, and a LINE alert when readings drift.

What you get: You can see the leak in the hours the compressor runs with nothing in production, judge whether the set pressure can come down, and plan maintenance on real run hours.
Fits: Manufacturing · Food plants · Paint and assembly · Compressor rooms

How it works

01
Sensors in the compressor room

Pressure, flow, dew point, and each compressor's power

Modbus · WiFi · 4G
02
Gateway

Collects the sensors and meters over WiFi or a 4G SIM

MQTT / HTTPS
03
Cloud

Every interval kept, including the nights and holidays that prove a leak

History
04
AI analysis

Momosight sets run hours against real production time, estimates the share leaking, and checks whether the set pressure is higher than needed

AI insight
05
Dashboard

Pressure, flow, energy per cubic metre, and the loaded-versus-unloaded split

LINE · Email
06
Alerts and reports

LINE when pressure falls or dew point climbs, with a monthly report

The platform also speaksBACnetDigital inputTelegram

What it does

Leaks proved with data

The hours the compressor runs with nothing in production show how much air is escaping — no guessing.

Energy per cubic metre

From measured power and flow: kWh per m³, and a fair comparison between machines.

Loaded against unloaded

The stretches where the compressor draws power without making air.

Pressure and dew point

System pressure and air quality watched, with warning when moisture threatens the work.

Run hours and service

Hours per machine, and a reminder at filter and oil intervals.

Many machines, many plants

Compare every compressor from one screen and decide which to run first.

Devices used in this system

Prices are per set; how many you need depends on the site.

Where it fits

General manufacturing

Air for machines and tools

Food plants

Air that must stay dry

Paint shops

Air quality shows in the finish

Assembly and packing

Many air tools at once

Central compressor rooms

Several machines alternating

Multi-building plants

Long pipe runs with many places to leak

How we work with you

  1. 01
    Survey the room

    The machines and their sizes, the receiver, the pipework, and where sensors can go.

  2. 02
    Install and check

    Pressure, flow and dew point sensors plus power meters fitted, then readings verified.

  3. 03
    Record a shutdown

    A night or a holiday recorded as the baseline for estimating the leak.

  4. 04
    Support afterwards

    Annual MA, with results and service intervals reviewed.

Related documents

Questions about this system

Does the air system have to be shut down?

Pressure sensors use existing tapping points. The flow meter depends on the type and the pipe run; we assess it on site and book a production break only if it is needed.

How accurate is the leak estimate?

It uses air volume and the hours the compressor runs while nothing is in production — the accepted approach in an air audit. It sizes the problem and its trend; finding each leak still needs someone walking the pipework.

Which compressor brands does it suit?

Any of them, measured externally — power, pressure and flow. Reading the machine's own controller depends on whether it offers Modbus or status contacts.

Does lowering the set pressure really save?

Lowering it reduces the energy used, but how much depends on the pressure the work actually needs — which the data shows before you decide. We do not recommend lowering it blind.